Faults, causes and remedies

Cause

Remedy

Fault: The pump is not priming.

Incorrect commissioning procedure.

See Filling and venting the hydraulics

The suction procedure can be from two seconds to five minutes.

Air intake into the suction line.

Examine the pipework for leaks.

Suction filter clogged.

Clean the suction filter

Integrated non-return valve in the suction port blocked (only LPC 50 and LPC 80).

Remove suction pipe and clean the non-return valve.

Suction height is too high.

Max. suction height is 7.5 m. Examine the operating conditions.

Fault: No or not sufficient flow rate

Suction filter clogged.

Clean the suction filter

Direction of rotation incorrect (counter-clockwise rotating field).

Examine mains connection. Clockwise rotating field necessary.

Gate valves are closed.

Open the gate valves in the suction pipe and discharge pipe.

Wear and tear at the hydraulics.

Contact customer service.

Fault: Motor protection switch tripped or the motor overheated.

Mains connection incorrect.

Examine the mains connection. Contact an electrician.

Motor circuit breaker incorrectly set

Examine the setup.

Phase failure.

Examine the mains connection. Contact an electrician.

Wear and tear at the hydraulics.

Contact customer service.