Replacing the cover cap and propeller blades
DANGER
Danger due to fluids hazardous to health during installation!
Danger of bacterial infection!
- Clean and disinfect installation location.
- Wipe up drips immediately.
- Observe the specifications of the factory regulations!
- If contact with fluids that are hazardous to health is possible, wear the following protective equipment:
- sealed safety glasses
- mouth protection
- safety gloves
NOTICE
Work steps for dismantling
The individual components are dismantled in reverse order to assembly.
Propeller blade replacement is performed with the mixer installed. Observe the following points:
- Prepare the operating space/installation site:
- Clean, free of coarse solids
- Dry
- Frost-free
- Decontaminated
- Work must always be carried out by two persons.
- Avoid any painful or tiring body postures.
- When working at a height of more than 1 m (3 ft) above the ground, use scaffolding with a safety harness.
- Cordon off the working area around the scaffolding.
- Toxic or asphyxiating gases may build up when working in closed rooms. Ensure there is sufficient ventilation and observe protective measures according to work regulations (examples):
- Measure the gas concentration before entering.
- Carry a gas detector with you.
- etc.
- Take immediate countermeasures if there is a build-up of toxic or asphyxiating gases.
- To remove/install the cover cap, see “Mounting the cover cap”.
- To remove/install the propeller blades, see “Attaching the propeller blades”.
- Inspect the individual propeller blades for wear. Replace all propeller blades if necessary. Consult customer service!
- Note the setting angle. A different angle changes the flow behaviour.