Installation
- Perform assembly so that the pump shaft is horizontal and not under strain!
- Make sure that the pump is installed in a permissible installation position and with the correct flow direction: Follow the direction of flow on the pump housing!
- Installation of pump only in permissible installation position!
- If necessary, rotate the motor including the control module, see section “Aligning the motor head”
![Observe the flow direction](../Images/jpg/191086859__Web.jpg)
![Permissible installation positions](../Images/jpg/191076875__Web.jpg)
CAUTION
Electronics breakdown due to drips
If the module is in a position that is not permitted, there is a risk of water drips entering the module. This can lead to a defect/breakdown of the electronics.
- The module is not allowed to be positioned with the cable connection pointing upwards!