Installing the flush connection
1 | Surface coupling |
2 | Gate valve |
3 | Flush connection (1") |
4 | Flush connection extension (L = 300 mm) |
5 | Flush connection (L = 300 mm) |
6 | Flush connection cover (dummy coupling Storz C-52) |
- The flush connection is installed directly on the surface coupling.
- The inlet is connected using a Storz coupling C-52.
- Remove the sealing plug on the 1" connection on the surface coupling.
- Apply a standard sealant (hemp, Teflon tape) around the thread on the flush connection.
- Screw the flush connection into the connection on the surface coupling.
- Remove the dummy coupling on the flush connection and connect the inlet.
If the flush connection is positioned too low, it can be adjusted using an extension. A dedicated number of extensions can be screwed together depending on the required height.