Connecting the inlet
1 | Inlet port |
To connect the inlet, follow these points:
- Make the connection at the supply box/distributor.
- To prevent surging inflow or air intake into the collection tank, install the inlet correctly.
- Make sure that the pipes are self-supporting: No tensile or compressive forces are applied on the inlet port.
- Make sure that all connections are fully tight.
- Make sure that the inlet pipe has a downward slope to the inlet box/distributor.
- Make sure to install a shut-off valve in the inlet pipe upstream of the supply box/distributor.
- The lifting unit is installed.
- The inlet pipe is installed as shown in the consulting documents.
- Route the inlet pipe to the supply box/distributor.
- Put a seal between the flange connectors.
- Fasten the flange connectors with screws. Tightening torque: 45 Nm (33.2 ft·lb).
- The inlet is connected. Next step: Connecting the ventilation pipe.