Monitoring devices
P13 | FK 17.1 | FK 202 | FKT 20.2 | Trigger action of warning | Trigger action of deactivation | |
---|---|---|---|---|---|---|
Motor compartment leakage detection | ||||||
Internal moisture probe | • | − | − | • | − | • |
Motor winding temperature monitoring | ||||||
Bimetallic sensor | • | • | • | − | − | • |
PTC sensor | o | o | o | • | − | • |
Motor bearings leakage detection | ||||||
Internal moisture probe | − | − | − | • | • | o* |
Sealing chamber leakage detection | ||||||
Internal moisture probe | • | − | − | • | • | o* |
External moisture probe | • | • | • | − | • | o* |
Key |
The exact details of the monitoring devices are shown in the respective configuration.
*Operating principle of temperature monitoring
- Temperature limiter - monitoring of one temperature level
- When the threshold is reached, the motor switches off. When the motor has cooled down, the motor can restart automatically.
- Automatic restart depends on local necessities (e.g. explosive atmosphere, local regulations, etc.) It can be necessary to switch off the motor with a reactivation lock. Obey the local necessities.
- Temperature control - monitoring of two temperature levels
- When the lower threshold is reached, the motor switches off. When the motor has cooled down, the motor restarts automatically.
- When the higher threshold is reached, the motor switches off with a reactivation lock. Automatic restart is not permitted.