Installation of a diaphragm hand pump
NOTICE
Do not connect inlets to the drain connection!
For maintenance work or if a system malfunctions, the tank is emptied through the drain connection. If an inlet is connected to the drain connection, the tank cannot be emptied.
Manually pump out the collection tank for maintenance or if the lifting unit malfunctions. It is recommended to install a diaphragm hand pump.
1 | Drain connection |
Follow these points to install a diaphragm hand pump:
- Obey the installation and operating instructions for the diaphragm hand pump.
- Make sure that all connections are fully tight.
- Installation height for optimum operation is set.
- Use a 30 mm (1.3 in) hole saw to drill the drain connection.
- Put the HT double socket on the open drain connection.
- Connect the inlet of the diaphragm hand pump to the HT double socket on the drain connection.
- Connect the outlet of the diaphragm hand pump to the discharge line above the shut-off valve. Alternatively, connect the outlet of the diaphragm hand pump through a pipe loop directly to the sewer.
- Diaphragm hand pump is installed.