Technical data

Approved field of application

Max. pressure in the discharge pipe

6 bar (87 psi)

Max. delivery head

See rating plate

Max. volume flow

See rating plate

Max inlet height of the lowest inlet

5 m (16.5 ft)

Fluid temperature

3 ... 40 °C (37 ... 104 °F)

Max. short-time fluid temperature

65 °C (149 °F), 5 min

Ambient temperature

3 ... 40 °C (37 ... 104 °F)

Protection class of lifting unit

IP68 (2 mWs/7 d)

Protection class of switchgear

IP54

Electrical data

Power consumption [P1]

See rating plate

Rated power [P2]

See rating plate

Rated current [IN]

See rating plate

Speed [n]

See rating plate

Activation type

Direct

Operating mode

S3 10%

  • Cycle time: 10 min
  • Activation period: 1 min
  • Downtime: 9 min

Maximum switching frequency

60/h

Cable length to plug

1.5 m (5 ft)

Cable length to switchgear

4 m (13.2 ft)

Connections

Discharge port

DN 32/40, PN 6; 40 mm, PN 6

Inlet connection

DN/OD 110; DN/OD 160

Ventilation connection

DN/OD 50

Drain connection

DN/OD 50

Dimensions and weights

Tank volume

64 l (16 US.liq.gal.)

Max. usable volume in the tank according to the inlet height*

29 l/7 US.liq.gal. (180 mm*)/39 l/10 US.liq.gal. (250 mm*)/48 l/12 US.liq.gal. (315 mm*)

Diagonal dimension

782/802 mm (31/31.5 in)

Weight

39.5 ... 54.5 kg (87 ... 120 lb)

Noise level

70 dB(A)

The unit is not designed for continuous duty (operation mode S1). The max. volume flow applies to intermittent periodic duty (operation mode S3).