Electrical connection
- Install protective earth conductor for mains connection. Obey local regulations.
- Install a residual-current device (RCD) with a trigger current of 30 mA.
- Use fuse protection at the mains connection with a maximum rating of 10 A.
- Make sure that the mains connection is compatible with the voltage (U) and frequency (f) data on the rating plate.
Do not connect the pump under the following conditions:
- The connection cable is damaged.
- To replace the damaged cable, contact a qualified electrician or customer service.
- A stand-alone inverter is used.
- A stand-alone inverter is used in autonomous power supplies, e.g., solar power supply. An inverter can cause overvoltage. Overvoltage destroys the pump.
- A power strip is used.
- An energy-saving plug is used.
- The plug decreases the power supply to the pump. The pump can overheat and be destroyed.
- A start-up control device is used.
- Do not connect the pump to a frequency converter or a soft starter. The pump is not designed for such operation.
- There is a potentially explosive atmosphere. The pump has no Ex approval.