Removal

DANGER

danger

Danger through bacterial infection!

There can be bacteria and hazardous germs in stagnant water. Follow these points:

  1. Keep the area properly ventilated.
  2. Wear a respiratory mask, e.g., Half mask 3M series 6000 with filter 6055 A2.
  3. Disinfect the pump.
  1. Empty the pit.
  2. Close all gate valves.
  3. Switch off the pump.
  4. Disconnect the pump from the mains.
  5. Disassemble the pump from the discharge line.
  6. Remove the pump from the site.
  7. Unscrew the discharge pipe/pressure hose from the discharge port.
  8. Coil up the connection cable and keep it at the pump.
  1. Pump removed. Clean the pump and the discharge pipe/pressure hose thoroughly.