Removal
DANGER
Risk of fatal injury due to electrical current!
Improper conduct when carrying out electrical work can lead to death due to electric shock!
- Before all electrical work, disconnect the product from the mains and secure it against being switched on again without authorisation.
- Disconnect the battery and insulate the plus contact.
- Electrical work must be carried out by a qualified electrician!
- Observe local regulations!
- Disconnect the switchgear from the mains supply − remove the mains plug.
- Remove the cover.
- Remove the blade connector from the plus contact (+) of the battery.
- Connect the grommet to the plus contact (+) of the battery.
- Disconnect all connection cables and pull them out of the threaded cable glands.
- Seal the threaded cable glands.
- Loosen the fastening screws and remove the switchgear.
- Put the cover back on and secure it.
- Switchgear removed.