Storage
DANGER
Danger of death from fluids hazardous to health!
Danger of bacterial infection!
- Disinfect the pump chamber after draining and before removal!
- Observe the specifications of the factory regulations!
- Drain the pump chamber completely.
- Place the pump chamber on a firm surface. Check the stability.
- Secure the pump chamber against falling over and slipping!
- Storage conditions:
- Maximum: -15 ... 60 °C (5 ... 140 °F), max. humidity: 90 %, non-condensing.
- Recommended: 5 ... 25 °C (41 ... 77 °F), relative humidity: 40 ... 50 %.
- Close all openings, ensuring they are sealed watertight.
- Do not store the pump chamber in spaces where welding work is carried out. The resulting gases or radiation can corrode the plastic parts.
- Protect the pump chamber from direct exposure to sunlight. Extreme heat can cause the plastic parts to deform!
If pumps or signal transmitters are installed, please also observe the following points:
- Seal the ends of the connection cables against water ingress.
- Coil up connection cables and attach in the pump chamber.
- Observe information on the max. storage temperature of the pumps and signal transmitters.
- Store the switchgear according to the manufacturer's instructions.