Oil change seal housing (TR 20-1/22/28-1, TRE 20)
+/- | Drain/fill seal housing oil |
- Protective equipment used!
- Mixer removed, cleaned and disinfected.
- Place mixer on a firm work surface in a horizontal position.
- Secure the mixer against falling over and slipping.
- Position a suitable tank to collect the operating fluid.
- Unscrew the screw plug (+/-).
- Tip the mixer and allow the operating fluid to drain out.
- Check the operating fluid:
- Operating fluid clear: Operating fluid can be reused.
- Operating fluid contaminated (black): fill with new operating fluid.
- Operating fluid milky/cloudy: Water in oil. Minor leakage through the mechanical seal is normal. If the ratio of oil to water is less than 2:1, the mechanical seal may be damaged. Change the oil and check again four weeks later. If water is again present in the oil during the second check, contact customer service!
- Metal chips in the operating fluid: Contact the customer service!
- Readjust the mixer so that the opening points upwards.
- Pour the new operating fluid in through the hole for the screw plug (+/-).
- Comply with the specifications for the operating fluid type and quantity.
- Clean the screw plug (+/-), replace the seal ring and screw it back in. Max. tightening torque: 8 Nm (5.9 ft·lb)!
- Restore corrosion protection: Seal screw plug, e.g. with Sikaflex.