Direction of rotation monitoring
The mixer is checked at the factory and set to the correct direction of rotation for a clockwise rotating field. Connection is made in accordance with the specifications in chapter “Electrical connection”.
Direction of rotation check
- Mains connection with clockwise rotating field present.
- Rotating field inspected by a qualified electrician.
- No persons are allowed in the working area of the mixer.
- Mixer securely installed.
- Propeller is visible.
- Switch on the mixer. Max. operation duration: 15 s!
- Direction of propeller rotation:
View from front: The propeller rotates anti-clockwise (to the left).
View from behind: The propeller rotates clockwise (to the right).
- Direction of rotation correct.
If the direction of rotation is false, change the connection as follows:
- Direct starting: swap two phases.
- Star-delta starting: swap connections of two windings (e.g. U1/V1 and U2/V2).