Installation
DANGER
Danger due to fluids hazardous to health during installation!
Ensure that the installation site is clean and disinfected during installation. If contact with fluids that are hazardous to health is possible, observe the following points:
- Wear protective equipment:
- sealed safety goggles
- mouth protection
- protective gloves
- Wipe up drips immediately.
- Observe the specifications of the work regulations.
DANGER
Risk of fatal injury due to dangerous lone working practices!
Work in chambers and narrow rooms as well as work involving risk of falling are dangerous work. Such work may not be carried out autonomously!
- Only carry out work with another person!
CAUTION
Material damage due to incorrect fixation
Defective fixation may limit the functionality of the mixer or damage it.
- If the mixer is fixed to a concrete structure, use anchor bolts for fixation. Follow the manufacturer’s installation instructions! Temperature specifications and hardening periods must be strictly observed.
- If the mixer is fixed to a steel structure, ensure that the structure is sufficiently strong. Use fixation materials with sufficient strength!
Use suitable materials to avoid electrochemical corrosion! - Tighten all screwed connections. Observe torque specifications.
- Wear protective equipment! Observe the work regulations.
- Protective gloves: 4X42C (uvex C500)
- Safety shoes: Protection class S1 (uvex 1 sport S1)
- Wear a safety harness.
- Safety helmet: EN 397 Conforms to standards, protection against lateral deformation (uvex pheos)
- (When using lifting equipment)
- Prepare the installation site:
- Clean, free of coarse solids
- Dry
- Frost-free
- Disinfected
- Work must always be carried out by two persons.
- Demarcate the working area.
- Keep unauthorised persons away from the working area.
- From a working height of more than 1 m (3 ft) above the ground, use scaffolding with a safety harness.
- Toxic or asphyxiating gases may build up during work:
- Observe protective measures in accordance with work regulations (gas measurement, carry a gas detector with you).
- Ensure adequate ventilation.
- If toxic or asphyxiating gases accumulate, leave the workplace immediately!
- Install lifting equipment: even surface, clean, firm base. Warehouse and installation location must be easily accessible.
- Attach chain or wire rope to handle/attachment point with a shackle. Only use lifting gear that has been technically approved.
- Do not stay within the swivel range of the hoisting gear.
- All connection cables must be laid properly. The connection cables must not pose any risk (i.e. tripping, damage during operation). Check whether the cable cross-section and the cable length are sufficient for the selected installation type.
- Observe minimum clearances to walls and any fixtures.