Min. inlet pressure

Minimum inlet pressure (above atmospheric pressure) at the pump’s suction port to avoid cavitation noises at fluid temperature:

Min. inlet pressure

Nominal diameter

Fluid temperature

-10 °C to +50 °C

+80 °C

+95 °C

+110 °C

Rp 1

0.3 bar

0.8 bar

1.0 bar

1.6 bar

Rp 1¼

0.3 bar

0.8 bar

1.0 bar

1.6 bar

DN 32 (Hmax = 8 m, 10 m, 12 m)

0.3 bar

0.8 bar

1.0 bar

1.6 bar

DN 32 (Hmax = 16 m)

0.5 bar

1.0 bar

1.2 bar

1.8 bar

DN 40 (Hmax = 4 m, 8 m)

0.3 bar

0.8 bar

1.0 bar

1.6 bar

DN 40 (Hmax = 12 m, 16 m)

0.5 bar

1.0 bar

1.2 bar

1.8 bar

DN 50 (Hmax = 6 m)

0.3 bar

0.8 bar

1.0 bar

1.6 bar

DN 50 (Hmax = 8 m)

0.5 bar

1.0 bar

1.2 bar

1.8 bar

DN 50 (Hmax = 9 m, 12 m)

0.5 bar

1.0 bar

1.2 bar

1.8 bar

DN 50 (Hmax = 14 m, 16 m)

0.7 bar

1.2 bar

1.5 bar

2.3 bar

DN 65 (Hmax = 6 m, 9 m)

0.5 bar

1.0 bar

1.2 bar

1.8 bar

DN 65 (Hmax = 12 m, 16 m)

0.7 bar

1.2 bar

1.5 bar

2.3 bar

DN 80

0.7 bar

1.2 bar

1.5 bar

2.3 bar

DN 100

0.7 bar

1.2 bar

1.5 bar

2.3 bar

NOTICE

Effective up to 300 m above sea level. For higher altitudes +0.01 bar/100 m.

In case of higher fluid temperatures, fluids of lower density, higher flow resistances or lower atmospheric pressure, adjust the values accordingly.

The maximum installation height is 2000 metres above MSL.