Cleaning the pump interior
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is a danger of cuts and similar injuries!
- Wear protective gloves!
In the case of severe dirt and encrustations, remove the cover plate on the suction port and clean the pump interior.
- Place the pump on a firm surface in a horizontal position.
- Secure the pump against slipping!
- Unscrew the 3 fastening screws on the cover plate.
- Remove the cover plate.
- Rinse the pump interior with clean, running water. Remove solids by hand.
- Check the O-ring on the suction port. If the O-ring is damaged (cracks, porosity, crushed areas), replace the O-ring.
- Position the cover plate on the suction port.
- Fully screw in the 3 fastening screws.
- Pump interior is cleaned and cover plate has been reattached. Complete the cleaning work.