Stationary wet well installation

  1. Close the gate valve in the inlet and pressure pipe.
  2. Switch off pump.
    Pump with a plug: Pull the plug.
    Pump firmly connected(without plug): Disconnect the pump from the mains. DANGER! Have electrical work carried out by a qualified electrician!
  3. Disconnect the connection cable from the pressure pipe.
  4. Release the pump and discharge pipe from the pressure pipe.
  5. Lift the pump by the handle out of the operating space.
  6. Unscrew the discharge pipe from the pressure port.
  7. Coil up the connection cable and store it with the pump.
  8. Clean pump and discharge pipe thoroughly.
  1. Pump removed.

If the pump remains installed, observe the following points:

  • Protect pump from frost and ice:
    • Immerse the pump completely in the pumped fluid.
    • Min. ambient temperature: +3 °C (+37 °F)
    • Min. fluid temperature: +3 °C (+37 °F)
  • If the pump will not be used for a prolonged period, switch on pump and carry out one pumping process every 2 months to prevent encrustations and clogging. Only carry out the pumping process under suitable operating conditions!

If the above points are not guaranteed, remove the pump!